Basic data | |||||||
---|---|---|---|---|---|---|---|
Series | MLD 500 | ||||||
Device type | Transceiver | ||||||
Special design | |||||||
Special design | Integrated muting indicator, Connection socket for external muting indicator, Integrated status indicator | ||||||
Functions | |||||||
Functions | Automatic restart | ||||||
Characteristic parameters | |||||||
Type | 4, IEC/EN 61496 | ||||||
SIL | 3, IEC 61508 | ||||||
SILCL | 3, IEC/EN 62061 | ||||||
Performance Level (PL) | e, EN ISO 13849-1 | ||||||
MTTFd | 204 years, EN ISO 13849-1 | ||||||
PFHD | 6.6E-09 per hour | ||||||
Mission time | 20 years, EN ISO 13849-1 | ||||||
Category | 4, EN ISO 13849 | ||||||
Protective field data | |||||||
Operating range | 0.5 ... 6 m | ||||||
Operating range in connection with MLD-XM03 | 0.5 ... 8 m | ||||||
Optical data | |||||||
Number of beams | 3 Piece(s) | ||||||
Beam spacing | 400 mm | ||||||
Light source | LED, Infrared | ||||||
LED light wavelength | 850 nm | ||||||
Transmitted-signal shape | Pulsed | ||||||
LED group | Exempt group in acc. with EN 62471:2008 | ||||||
Electrical data | |||||||
Protective circuit | Overvoltage protection, Short circuit protected | ||||||
Performance data | |||||||
Supply voltage UB | 26.5 ... 31.6 V | ||||||
Current consumption from AS-i circuit | 140 mA | ||||||
Protective circuit | Overvoltage protection, Short circuit protected | ||||||
Outputs | |||||||
Number of digital switching outputs | 1 Piece(s) | ||||||
Switching outputs | |||||||
Type | Digital switching output | ||||||
Switching voltage high, min. | 18.2 V | ||||||
Switching voltage low, max. | 2.5 V | ||||||
Switching voltage, typ. | 23 V | ||||||
Voltage type | DC | ||||||
Number of digital switching outputs | 1 Piece(s) | ||||||
Protective circuit | Overvoltage protection, Short circuit protected | ||||||
Timing | |||||||
Response time | 30 ms | ||||||
Restart delay time | 100 ms | ||||||
Interface | |||||||
Type | AS-Interface Safety at Work | ||||||
AS-i | |||||||
Function | Process | ||||||
AS-i profile | S-7.B.1 | ||||||
Slave address | 1..31 programmable, default=0 | ||||||
Cycle time acc. to AS-i specifications | Max. 5 ms | ||||||
Type | AS-Interface Safety at Work |