Регистрация
deal.by
Read/write station IQT1-FP-IO-V1 - фото 1 - id-p95199008
Характеристики и описание

Техническая спецификация в PDF  

Описание оборудования

HF read/write station with IO-Link in accordance with ISO 15693

General specifications

Operating frequency13.56 MHz
Transfer rate26 kBit/s
Sensing range
UL File NumberE87056

Functional safety related parameters

MTTFd680 a
Mission Time (TM)10 a
Diagnostic Coverage (DC)0 %

Indicators/operating means

LED red/greenGreen: power on
Flashing green: IO-Link communication
Flashing red/green: IO-Link communication interrupted
LED blue/yellowBlue: Write/read attempt performed
Yellow: Read/write tag detected

Electrical specifications

Rated operating voltage20 ... 30 V DC , ripple10%SS
Power consumption? 2 W

Interface

Interface typeIO-Link
ProtocolIO-Link V1.1
Cycle timemin. 4 ms
ModeCOM3 (230.4 kBaud)
Process data witdh32 Byte
SIO mode supportno

Directive conformity

Electromagnetic compatibility
Radio and telecommunication terminal equipment

Standard conformity

Degree of protectionEN60529:2000
RFIDISO/IEC 15693-2:2006
ISO/IEC 15693-3:2009
ISO/IEC 18000-3:2010

Approvals and certificates

UL approvalcULus Listed, Class 2 Power Source, Type 1 enclosure
FCC approvalThis device complies with pИли отправьте нам запрос наeration is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation.
Caution:
Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
IC approvalThis device complies with Industry Canada licence-exempt RSS standard(s) and with pИли отправьте нам запрос наeration is subject to the following two conditions:
(1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may cause undesired operation of the device.

Le present appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisee aux deux conditions suivantes :
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage radioelectrique subi, meme si le brouillage est susceptible d'en compromettre le fonctionnement.
Radio approvalUSA: FCC IREIQT1FPIO
Canada: 7037A-IQT1FPIO

Ambient conditions

Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)

Mechanical specifications

Degree of protectionIP67
ConnectionM12 x 1 connector
Material
Installation
Massapprox. 380 g

 

По вопросу интересующей Вас продукции, пожалуйста, свяжитесь с нами:

  

8 (029) 555-8-000

Был online: Давно
OOO "ФилФар Технолоджи"
Рейтинг не сформирован
10 лет на Deal.by

Read/write station IQT1-FP-IO-V1

Под заказ
Цену уточняйте
Доставка
Оплата и гарантии

У нас покупают

Read/write station IQT1-FP-IO-V1 в Могилевской области