Описание оборудования | |
---|---|
Single head system | |
General specifications | |
Sensing range | 30 ... 500 mm |
Adjustment range | 50 ... 500 mm |
Dead band | 0 ... 30 mm |
Standard target plate | 100 mm x 100 mm |
Transducer frequency | approx. 380 kHz |
Response delay | ? 50 ms |
Indicators/operating means | |
LED green | solid green: monitoring system green flashing: program function |
LED yellow | indication of the switching state flashing: program function object detected |
LED red | flashing: normal mode: error Program function: no object detected permanently: Program mode, object uncertain |
Electrical specifications | |
Operating voltage | 10 ... 30 V DC , ripple10%SS |
No-load supply current | ? 55 mA |
Input/Output | |
Synchronization | 1 synchronous input 0 level: UB...+1 V 1 level: +4 V...+UB input impedance: > 12 KOhm synchronization pulse: 0.1 ... 8 ms |
Synchronization frequency | |
Input | |
Input type | 1 program input, switching point A1: -UB ... +1 V, switching point A2: +4 V ... +UB input impedance: > 4.7 k?, program pulse: ? 1 s |
Output | |
Output type | 1 switch output E4, NPN, NO/NC |
Rated operating current | 200 mA , short-circuit/overload protected |
Voltage drop | ? 3 V |
Repeat accuracy | ? 1 % of full-scale value |
Switching frequency | max. 10 Hz |
Range hysteresis | ? 1 % of the set operating distance |
Temperature influence | ± 1.5 % of full-scale value |
Approvals and certificates | |
UL approval | cULus Listed, General Purpose |
CSA approval | cCSAus Listed, General Purpose |
CCC approval | CCC approval / marking not required for products rated ?36 V |
Ambient conditions | |
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
Mechanical specifications | |
Connection type | Connector M12 x 1 , 5-pin |
Degree of protection | IP65 |
Material | |
Mass | 100 g |
8 (029) 555-8-000 | |
8 (044) 555-8-000 | |
8 (017) 255-8-000 |